Our semi-automatic distillation apparatus is engineered to meet a range of industry standards and deliver reliable, precise atmospheric distillation analysis for volatile products.
Standards Compliance
- International Standards: ASTM D86, ASTM D850, ASTM D1078, ISO 3405, IP 123, IP 195
Applications
This apparatus is designed for efficient atmospheric pressure distillation analysis of:
- Gasoline, fuel, and oil
- Solvents, aromatics, naphtha, kerosene
- Hydrocarbons and other volatile substances
The system enables controlled evaporation and condensation at atmospheric pressure, allowing for accurate observations of recovery percentages and corresponding temperatures.
Salient Features
- Elegant and Durable Design: Aesthetic exterior with an attractive, powder-coated finish.
- User-Friendly & Economical: Combines ease of use with cost-efficiency for practical applications.
- Enhanced Heating and Cooling:
- Flask heater compartment with integrated cooling fan
- Smooth flask-lifting mechanism
- Long-lasting, low-voltage heating coil with precise power adjustment via potentiometer
- Temperature Precision: Equipped with CLASS-A, PT-100 vapor temperature sensor and indicator (standard) for accurate readings.
- Condensation Control: Temperature control for condenser and receiver section, with an in-built refrigeration system for consistent cooling.
- Safety Features:
- Manual fire extinguisher (requires external N2/C2 source)
- Optical sensor with audible beep for Initial Boiling Point (IBP) detection and drop monitoring, with LED flashing indicator for added visibility.
- Convenient Operation:
- Operates on 230 Volts, 50 Hz, single-phase AC supply
- Power consumption: 1400 Watts
- Glass PT-100 vapor temperature probe with digital indicator and automatic barometric correction for precise measurements.
This semi-automatic distillation apparatus combines reliable functionality with modern safety and user-friendly features, making it ideal for laboratories conducting routine atmospheric distillation analyses.
Distillation group |
0 to 4 solvents |
Work temp |
0 °C to 450 °C |
Vapor temp |
0 °C to 450 °C, Accuracy : ± 0.1 °C |
Temp sensor |
PT-100 Probe, Class A |
Display |
Digital temperature controller cum indicator |
Sample Volume |
Optical measuring system, 0 to 103% of charge volume |
Volume resolution |
0.1 ml |
Distillation rate |
2-15 ml/min (Programmable) |
Dry point |
In-built dry point detection probe |
Pressure correction |
Range 700 to 1100 hpa (500 to 800 mm of hg) |
Condenser temperature |
0-80 °C (Programmable), Accuracy : ± 0.5 °C |
Receiver temperature |
0-60 °C (Programmable), Accuracy : ± 0.5 °C |
Operating Temperature |
10 - 35 Accuracy : ± 0.5 °C |
Power Supply |
230 volts, 50 hz, single phase, AC Supply |