Compliance Standards:
ASTM D6931
Principle:
The Indirect Tensile Strength is determined by measuring the ultimate load to failure of a specimen, which is subjected to a constant deformation rate of 50.8 mm/minute on its diametrical axis according to ASTM D6931.
Apparatus details:
The LOTMAN Breaking head assembly with Guide rods and loading strips FOR 6" DIA Specimen will be supplied. The Marshal Machine, water bath, Oven etc. required for test will not be part of this supply.