PH METER-TABLE TOP - MICROPROCESSOR BASED-(0.01 PH)-(ATC)-(THREE POINT CALIBRATION)-(LMPH 10H))

PH METER-TABLE TOP - MICROPROCESSOR BASED-(0.01 PH)-(ATC)-(THREE POINT CALIBRATION)-(LMPH 10)-

Model No: LMPH10H

Bench top pH Meter with 3 point calibration, Big LCD Display, Auto Buffer recognition, simultaneous display of pH and Temp; Automatic Temp.compensation, Hold, Reset and Auto OFF Function, USA or NIST Buffer option, Help message on screen. Measuring range : -2 to 16 pH, Accuracy ± 0.01 pH, Supplied with pH Electrode, Liquid Calibration pH Buffer Bottle ( 4.01, 7.00 pH), Temperature Probe, Electrode Stand, 9 V Power adapter, Instruction Manual. Further details and Instrument image mentioned as under

LMPH10H-pH meter is large LCD display with white back light. It can displays many useful prompt messages to helps you quickly and easily measuring the samples.


Silent Features:


  1. During the pH mode, Up to 3 points push-button calibration with auto- buffer recognition. (USA & NIST Buffer)
  2. Selectable pH buffer standards and temperature units.
  3. Automatically Electrode diagnosis shows the pH slope and offset.
  4. Automatic Temperature Compensation (ATC) ensures highly accurate measurement over the entire range.
  5. Automatic endpoint function freezes the stable measured values.
  6. Help message as an operational guide to help you to understand how to use meter.
  7. Setup menu allows setting pH Buffer set, number of calibration point, temperature, unit etc. user customizes buffer standards, calibration points, stability conditions, resolution, temperature units, date and time to meet measurement requirements.
  8. Reset function can resumes all settings to factory default values.
  9. Expanded memory stores and recalls up to 100 readings.
  10. USB Interface.


IMPORTANT NOTE FOR MAINTENANCE OF PH ELECTRODE


To ensure an optimum response time, the glass sensor tip and the reference junction of the pH electrode should be kept moist and not be allowed to dry out when not in use. Placing the electrode in a small glass filled with pH storage solution or replacing the solution in the protective cap is a suitable way to store the electrode. It is recommended to rehydrate the electrode after a cleaning procedure by soaking for at least one hour before taking measurements. pH Storage solution can be supplied at extra cost


Modes

pH, mV, Temperature

pH Range

-2.00 to 16.000pH

pH Resolution

0.01 pH

pH Accuracy

±0.01 pH

Calibration

upto 3 points

pH Buffer options

USA (pH 4.01, 7.00, 10.01)pH Buffer NIST (pH 4.01, 6.86, 9.18)

Automatic Buffer Recognization

Yes

pH Slope Display

Yes

mV Range

± 1999 to 1999 mV

mV Accuracy

±1 mV

mV Resolution

1 mV

Temp. Range

0 to 105°C

Temp. Accuracy

±0.5°C

Operating Temperature

10 to 40°C

Relative humidity

< 80%

Reset Function

Yes

Interface

USB

Hold Function

Automatic at end point or Manual

Memory

upto 100 readings

Connector

BNC

Display

LCD with White Back Light

Display Size

125 × 100 mm

Power Supply

DC 5V adapters, using AC 220V / 50Hz,

Packing Dimensions (LxWxH )

300 × 245 × 185 mm

Net Weight / Gross Weight

0.65kg / 1.68kg

INQUIRE NOW
name
company name
state
Email
Mobile number
product name
message
Reset

Inquiry right arrow Inquiry left arrow INQUIRY

catalogue-image