PH METER-TABLE TOP - MICROPROCESSOR BASED-0.01 PH-ATC-TWO POINT CALIBRATION-PM-300

PH METER-TABLE TOP - MICROPROCESSOR BASED-0.01 PH-ATC-TWO POINT CALIBRATION-PM-300

Model No: PM-300

Digital pH Meter, Detailed Specifications as mentioned in the following page.

Features :

  1. High performance, high resolution microprocessor controlled pH meter.
  2. More sophisticated than ordinary pH meters.
  3. Very simple to operate
  4. Automatic pH standardization.
  5. Automatic & Manual temperature compensation.
  6. Temperature read‑out with pH value for complete sample information.
  7. Microprocessor based system for speed and accuracy.
  8. Automatic standard buffer recognition.
  9. Two point calibration
  10. The unit retains calibration points even when there is a power failure or the unit is switched off, Battery backup memory.
  11. No complex manual adjustment and calibration.
  12. Automatically checks the electrode behaviors, error indications with buzzer sound, and alerts you to problems.
  13. Soft touch key operation with beep sound.
  14. Facility to measure Redox potential in mV REL mode.
  15. Facility of general purpose millivolt meter in mV ABS mode.
  16. printer interface for hard copy (optional),with programmable sample number & time interval.
  17. Computer RS232 serial port (optional).
  18. The unit is housed in a compact and light weight attractive one peace fiberglass / Plastic cabinet.


IMPORTANT NOTE FOR MAINTENANCE OF PH ELECTRODE


To ensure an optimum response time, the glass sensor tip and the reference junction of the pH electrode should be kept moist and not be allowed to dry out when not in use. Placing the electrode in a small glass filled with pH storage solution or replacing the solution in the protective cap is a suitable way to store the electrode. It is recommended to rehydrate the electrode after a cleaning procedure by soaking for at least one hour before taking measurements. pH Storage solution can be supplied at extra cost


pH Range

0 to 14 pH

Millivolt range

0 to +1999 mV or + 1999.9 (optional - at extra cost)

Temperature Range

0℃ to 100℃ (Auto / Manual)

Calibration Points

2 Point Calibration

Resolution

pH

0.01 pH

mV

1.0 mV

Temperature

0.1 ℃

Repeatability

+0.01 pH + 1 digit

+1.0 mV or + 1digit

+0.2 ℃ + 1digit

Stability

0.01pH per hour.

Standard Buffers

7pH, and 4pH or 9.2 pH. or 1.68 pH or 12.45 pH*

Acceptable buffer deviation

+0.5pH approx

Display

7 digits, 7-segment LEDs (3 for temp. and 4/5 for pH) with auto-polarity, decimal point and unit annunciation by LED.

Power Supply

230V AC+10%,50Hz

Accessories

pH Electrode (0 to 14 pH) - Temperature probe, - pH Buffer Tablets - Electrode stand & clamp - Instruction manual, Dust Cover

Dimensions

320mm(w) x 280mm(D) x130mm(H)

Weight

2.5 kg. Approx

INQUIRE NOW
name
company name
state
Email
Mobile number
product name
message
Reset

Inquiry right arrow Inquiry left arrow INQUIRY

catalogue-image