BOMB CALORIMETER - AUTO CALCULATION WITH PRINTER AND PC INTERFACE – (WITH 0.001°C TEMP RESOLUTION)

BOMB CALORIMETER - AUTO CALCULATION WITH PRINTER AND PC INTERFACE – (WITH 0.001°C TEMP RESOLUTION)

Model No: SABC-292R

Detailed specifications are as follow:

As per IS:1448(Part 6) / IS:1350 (Part 2)


The system will consist of the following parts and standard accessories along with instruction manual.

  1. Calorimeter vessel with bomb support & insulating base - 01
  2. Water Jacket - 01
  3. Combined lid for calorimeter vessel & water jacket - 01
  4. Stirrer - 01 set
  5. Connecting lead for calorimeter bomb - 01 set
  6. Fine adjustment valve with built in pressure gauge - 01
  7. Connecting tube to connect bomb, pressure gauge and fine regulating valve - 01
  8. Safety Relief Valve fitted on gas filling tube adapter - 01
  9. Pellet Press - 01
  10. Spanner for Oxygen tube connection - 01
  11. Ignition Wire - Nichrome - 01 Roll of 5 meter
  12. Cotton Thread - 01 Roll
  13. Stand for Bomb Lid - 01
  14. Hook for Lifting Bomb - 01
  15. Crucible SS  - 01
  16. Gas Release Valve - 01
  17. Bomb Firing Unit - 01 Set
  18. Differential Type Digital Thermometer complete with sensor -01 No
  19. O-ring for bomb & valve - 01 set each
  20. Schrader Valve with Key - 01 each
  21. Standard Benzoic Acid - 01 Bottle

Salient Features of Microprocessor based controller

  1. Eliminates manual calculations
  2. Microprocessor based controller executes automatic calculations of Calorific Value
  3. Temperature resolution of 0.001°C  will be obtained.
  4. Results can be printed on In-Built THERMAL PRINTER and can be transferred to PC.
  5. Automatic measurement and calculation of CALORIFIC VALUE / WATER EQUIVALENT
  6. JUMBO size 16 x 2 characters LCD display with back-light.
  7. Inbuilt RTC (Real Time Clock) which makes note of time and date of test.
  8. Thermal printer interface for printing the final result.
  9. Thermal printer Printout Report Format for SAMPLE TEST
  10. COMPANY NAME & LOGO
  11. TYPE OF TEST : SAMPLE TEST
  12. MAX. TEMPERATURE RISE
  13. MASS OF TABLET
  14. WATER EQUIVALENT
  15. FINAL CALCULATED CALORIFIC VALUE
  16. DATE & TIME OF TEST
  17. Thermal printer Printout Report Format for Water Equivalent Test
  18. COMPANY NAME & LOGO
  19. TYPE OF TEST : WATER EQUIVALENT TEST
  20. MAX. TEMPERATURE RISE
  21. MASS OF TABLET
  22. BENZOIC ACID CALORIFIC VALUE
  23. FINAL CALCULATED WATER EQUIVALENT
  24. DATE & TIME OF TEST
  25. 16 soft-touch Keypad for Menu driven settings of different parameters
  26. Automatic measurement and mathematical calculation of the calorific value/Water Equivalent; which eliminates the requirement of operator to be continuously present to note the maximum temperature rise & to do the calculations manually.
  27. Weight of tablet feed able through keypad by user.
  28. Water equivalent settable through keypad by user.
  29. Automatic calculation for Sample Test or Water Equivalent Test from maximum temperature rise value.
  30. Full test report printout with date and time .
  31. Sensor open detection.
  32. Fuse wire open detection.
  33. User friendly system handling messages on LCD
  34. Type of test selectable
  35. Internal Data Logger THROUGH Computer Interface.
  36. PC Software for Data Record

Note: Resolution of 0.001°C Will be provided.

Pre-Installation Requirements for all Bomb Calorimeters to be arranged by you:

  1. Digital Top Pan Balance (0.0001 gm.)
  2. 2 KVA UPS with Batteries (30 min backup).
  3. RO (50 liter) approx.
  4. Oxygen Cylinder 99.9% Purity (47L, minimum 70 kg/cm2 pressure).
  5. Clean Dust Free Room, Solid vibration free working table away from windows, ovens and other heat generating source.
  6. Any others consumable etc.

Click here for working video : https://www.youtube.com/watch?v=CxosLXJE3vs&t=149s


Micro-Processor Based Yes
Automatic CV Calculation Yes
Maximum Temperature Rise Display Yes
Display Type Graphic LCD 128x64
Temperature Range Amb. To 55°C
Temperature Resolution 0.001°C
In-Built Thermal Printer Yes
Auto Gas Filling No
Digital Pressure Gauge No
Single Electronic Unit N.A.
Pressure Sensor N.A.
Alarm Audio/Visual Yes
Data Logging (1000 Logs) Yes
USB Interface Yes
PC Software Included Yes
PDF Report Generation Yes
Fuse Wire Error Adjustable Yes
Cotton Thread Error Adjustable Yes
Benzoic Acid Test Yes
Water Equivalent Test Yes
Weight of sample Settable Yes
Sensitivity Setting Yes
Fuse Open Detection Yes
Real Time Clock Yes
Warranty 1½ Years

INQUIRE NOW