VERTICAL AUTOCLAVES-GMP-SEMI AUTOMATIC-(55 X 90 CM)-(D X H)

VERTICAL AUTOCLAVES-GMP-SEMI AUTOMATIC-(55 X 90 CM)-(D X H)

Model Number : EIE-206SA213

None


SEMI AUTOMATIC, Double walled, single chamber for steam and water. Working chamber made of stainless steel 304 grade of 2 mm thickness. Outer cover made of stainless steel 1 mm thick. Lid, flange & bottom sheet also made of stainless steel. All joints argon welded.,Joint less silicon gasket, Heavy duty industrial flange heater. Pressure range: 15 to 22 PSI, factory set at 15 PSI. , Microprocessor based digital display. Temp. indicator cum controller with PT – 100 sensor. Temperature Range: 121°C to 125°C, resolution: 0.1°C . Accuracy ± 0.5°C.. Lid fitting pressure gauge 0 -30 PSI, safety spring loaded pressure valve with extra high pressure safety valve to double check against safety valve failure, steam release valve. Hydraulically tested at 60 PSI., Foot lifting arrangement included, Working on 230V/15A/50 Hz. Calibration certificate for pressure gauge and Digital Temp. indicator provided, Temperature automatically maintained by digital controller, which controls pressure and temperature with temperature indication, factory set at 121 °C (15 PSI) ,along with built in digital timer adjustable for maintaining sterilization cycle time with auto cut off. Low water cut off provided to safeguard heaters against accidental burn out,On site Validation and IQ/OQ/PQ documentation at extra cost.


Salient Features :

  1. Double wall design
  2. Single chamber for steam generation and water storage
  3. Working chamber made of stainless steel LM - 304 grade having 2mm thickness.
  4. Exterior Body is made of stainless steel LM - 304 grade having 1mm thickness.
  5. Lid, flange & bottom sheet also made of stainless steel. All  joints argon welded.
  6. Joint less silicon gasket.
  7. Heavy duty industrial flange heater.
  8. Semi Automatic operation; Manual steam release at the end of completion of cycle.
  9. Microprocessor based Digital Temperature Indicator cum Controller.
  10. PID Controller Controls temperature/pressure precisely at set value.
  11. Lid fitting pressure gauge 0-30 PSI, safety spring loaded mechanical pressure  valves.
  12. Complete unit is Hydraulically tested at 60 PSI pressure.
  13. Supplied with Calibration certificate with traceability
  14. Provided with DQ, IQ, OQ, PQ documentation (Optional for pharma industries)
  15. Validation ports provided for temperature mapping as standard supply. (On-site validation will be at extra cost. Please refer to optional accessories)


Safety features :


  1. Low water level heater safeguard.
  2. Low water level cut off
  3. Safety high pressure release valve (Spring loaded mechanical valves)
  4. Safety high temperature cut off.