FLAME PHOTOMETER - 1385E-

FLAME PHOTOMETER - 1385E-

Model No: 1385

Microprocessor Flame Photometer (2F) with Sodium (Na) & Potassium (K) filters, up to 5 point calibration, direct readout in ppm & meq/l, auto filter selection, auto ignition, auto flame failure detection, automatic gas cut-off function, 20x4 line LCD display, Single Aspiration, printer attachment facility supplied with compressor and other accessories for lab & medical use. RS232 Professional PC software for Computer Interface available at extra cost. Detail Specification as per following page. Note: Double distilled water and LPG gas cylinder is required at the time of demonstration of flame photometer.

SALIENT FEATURES:

  1. Microprocessor Based with Printer Interface
  2. Auto Gas Cutoff
  3. Auto Flame Failure Detection
  4. Four Measurements in Single Aspiration
  5. Setup Storage Facility
  6. Sample Data Storage Facility
  7. Curve Calibration Programmability Using Maximum of 5 Standards
  8. Multiple Calibration Curve Saving Facility
  9. Data Processing Through Curve Fitting Techniques, Least Square, Quadratic
  10. Online Help Key
  11. Direct Results in ppm and meq
  12. Useful for Medical & Soil Testing


TECHNICAL SPECIFICATION:


GENERAL RANGE

  1. ppm               meq/I
  2. Na: 0-100           Upto 250meq/I, 1:100 dil
  3. K: 0-100            Upto 250meq/I, 1:100 dil
  4. Ca: 0-100           Upto 250meq/I, 1:100 dil
  5. Li: 0-100            Upto 250meq/I, 1:100 dil
  6. Ba: 50-1000                     -


SERUM RANGE

  1. ppm               meq/I
  2. Na: 0-100           Upto 200meq/I, 1:100 dil
  3. K: 0-100            Upto 10meq/I, 1:100 dil
  4. Ca: 0-100            -
  5. Li: 0-100            Upto 0-2meq/I, 1:5 dil
  6. Ba: 50-1000          -


URINE RANGE

  1. ppm                meq/I
  2. Na: 0-100            Upto 250meq/I, 1:100 dil
  3. K: 0-100             Upto 100meq/I, 1:100 dil
  4. Ca: 0-100            Upto 10meq/I, 1:100 dil
  5. Li: 0-100              -
  6. Ba: 50-1000           -
  7. Sensitivity: General: Na: 0.5 ppm, K: 0.5 ppm, Li: 0.5 ppm, Ca: 15 ppm
  8. Filters: Na & K supplied (Ca & Li are optional at extra cost)
  9. Resolution: 0.1 ppm/meq
  10. Reproducibility:< 1% coefficient of variation for 20 consecutive samples using 10 ppm Na set as maximum standard
  11. Linearity: 2% error when 3 ppm Na/K and 5 ppm Li are set as maximum standard
  12. Curve Fit: +/- 2% of FS


Accuracy:

  1. Display:20 x 4 alphanumeric LCD with backlit
  2. Average Time: In-built in software
  3. Flame System: LPG and dry oil free air
  4. Detector: Silicon photodiode
  5. Calibration: Up to 5-Point calibration with curve fitting software
  6. Gas Control: Adjustable with knobs
  7. Flame Failure: Auto detection
  8. Gas Cutt off: Automatic
  9. Ignition System: Auto ignition
  10. Automizer :Axial flow type
  11. Printer: Provision for attachment of dot matrix printer or HP laser jet/ inkjet (non-windows) printers with Centronics parallel interface
  12. RS-232C:Available (PC software at extra cost)
  13. Power:230 V + 10% AC, 50 Hz
  14. Dimensions:365 x 245 x 220 mm (L x B x H) (Approx.)
  15. Weight: Main Unit: 9Kg. (Approx.)


Note :

Moreover, we request to you make necessary arrangement of prerequisites LPG gas cylinder with regulator, double distilled water, NACL LR grade, KCL LR grade, NA standard solution 2 ppm, 4 ppm, 6 ppm, 10 ppm and K standard solution 10 ppm, power supply 230 volt, 50 Hz 25 Amp power plug to carry out the said demonstration favorably.


INQUIRE NOW
name
company name
Email
Mobile number
product name
message
Reset

Inquiry right arrow Inquiry left arrow INQUIRY

catalogue-image