SALIENT FEATURES:
- Microprocessor Based with Printer Interface
- Auto Gas Cutoff
- Auto Flame Failure Detection
- Four Measurements in Single Aspiration
- Setup Storage Facility
- Sample Data Storage Facility
- Curve Calibration Programmability Using Maximum of 5 Standards
- Multiple Calibration Curve Saving Facility
- Data Processing Through Curve Fitting Techniques, Least Square, Quadratic
- Online Help Key
- Direct Results in ppm and meq
- Useful for Medical & Soil Testing
TECHNICAL SPECIFICATION:
GENERAL RANGE
- ppm meq/I
- Na: 0-100 Upto 250meq/I, 1:100 dil
- K: 0-100 Upto 250meq/I, 1:100 dil
- Ca: 0-100 Upto 250meq/I, 1:100 dil
- Li: 0-100 Upto 250meq/I, 1:100 dil
- Ba: 50-1000 -
SERUM RANGE
- ppm meq/I
- Na: 0-100 Upto 200meq/I, 1:100 dil
- K: 0-100 Upto 10meq/I, 1:100 dil
- Ca: 0-100 -
- Li: 0-100 Upto 0-2meq/I, 1:5 dil
- Ba: 50-1000 -
URINE RANGE
- ppm meq/I
- Na: 0-100 Upto 250meq/I, 1:100 dil
- K: 0-100 Upto 100meq/I, 1:100 dil
- Ca: 0-100 Upto 10meq/I, 1:100 dil
- Li: 0-100 -
- Ba: 50-1000 -
- Sensitivity: General: Na: 0.5 ppm, K: 0.5 ppm, Li: 0.5 ppm, Ca: 15 ppm
- Filters: Na & K supplied (Ca & Li are optional at extra cost)
- Resolution: 0.1 ppm/meq
- Reproducibility:< 1% coefficient of variation for 20 consecutive samples using 10 ppm Na set as maximum standard
- Linearity: 2% error when 3 ppm Na/K and 5 ppm Li are set as maximum standard
- Curve Fit: +/- 2% of FS
Accuracy:
- Display:20 x 4 alphanumeric LCD with backlit
- Average Time: In-built in software
- Flame System: LPG and dry oil free air
- Detector: Silicon photodiode
- Calibration: Up to 5-Point calibration with curve fitting software
- Gas Control: Adjustable with knobs
- Flame Failure: Auto detection
- Gas Cutt off: Automatic
- Ignition System: Auto ignition
- Automizer :Axial flow type
- Printer: Provision for attachment of dot matrix printer or HP laser jet/ inkjet (non-windows) printers with Centronics parallel interface
- RS-232C:Available (PC software at extra cost)
- Power:230 V + 10% AC, 50 Hz
- Dimensions:365 x 245 x 220 mm (L x B x H) (Approx.)
- Weight: Main Unit: 9Kg. (Approx.)
Pre-installation requireements :
We request to you make necessary arrangement of prerequisites LPG gas cylinder with regulator, double distilled water, NACL LR grade, KCL LR grade, NA standard solution (Minimum 5 solution Viz. 2 ppm, 4 ppm, 6 ppm, 10 ppm or as per requirement) and K standard solution (Minimum One Viz. 10 ppm or as per requirement), power supply 230 volt, 50 Hz 25 Amp power plug to carry out the demonstration at your site