FLAME PHOTOMETER - 1385E-

FLAME PHOTOMETER - 1385E-

Model Number : 1385

None


SALIENT FEATURES:

  1. Microprocessor Based with Printer Interface
  2. Auto Gas Cutoff
  3. Auto Flame Failure Detection
  4. Four Measurements in Single Aspiration
  5. Setup Storage Facility
  6. Sample Data Storage Facility
  7. Curve Calibration Programmability Using Maximum of 5 Standards
  8. Multiple Calibration Curve Saving Facility
  9. Data Processing Through Curve Fitting Techniques, Least Square, Quadratic
  10. Online Help Key
  11. Direct Results in ppm and meq
  12. Useful for Medical & Soil Testing


TECHNICAL SPECIFICATION:


GENERAL RANGE

  1. ppm               meq/I
  2. Na: 0-100           Upto 250meq/I, 1:100 dil
  3. K: 0-100            Upto 250meq/I, 1:100 dil
  4. Ca: 0-100           Upto 250meq/I, 1:100 dil
  5. Li: 0-100            Upto 250meq/I, 1:100 dil
  6. Ba: 50-1000                     -


SERUM RANGE

  1. ppm               meq/I
  2. Na: 0-100           Upto 200meq/I, 1:100 dil
  3. K: 0-100            Upto 10meq/I, 1:100 dil
  4. Ca: 0-100            -
  5. Li: 0-100            Upto 0-2meq/I, 1:5 dil
  6. Ba: 50-1000          -


URINE RANGE

  1. ppm                meq/I
  2. Na: 0-100            Upto 250meq/I, 1:100 dil
  3. K: 0-100             Upto 100meq/I, 1:100 dil
  4. Ca: 0-100            Upto 10meq/I, 1:100 dil
  5. Li: 0-100              -
  6. Ba: 50-1000           -
  7. Sensitivity: General: Na: 0.5 ppm, K: 0.5 ppm, Li: 0.5 ppm, Ca: 15 ppm
  8. Filters: Na & K supplied (Ca & Li are optional at extra cost)
  9. Resolution: 0.1 ppm/meq
  10. Reproducibility:< 1% coefficient of variation for 20 consecutive samples using 10 ppm Na set as maximum standard
  11. Linearity: 2% error when 3 ppm Na/K and 5 ppm Li are set as maximum standard
  12. Curve Fit: +/- 2% of FS


Accuracy:

  1. Display:20 x 4 alphanumeric LCD with backlit
  2. Average Time: In-built in software
  3. Flame System: LPG and dry oil free air
  4. Detector: Silicon photodiode
  5. Calibration: Up to 5-Point calibration with curve fitting software
  6. Gas Control: Adjustable with knobs
  7. Flame Failure: Auto detection
  8. Gas Cutt off: Automatic
  9. Ignition System: Auto ignition
  10. Automizer :Axial flow type
  11. Printer: Provision for attachment of dot matrix printer or HP laser jet/ inkjet (non-windows) printers with Centronics parallel interface
  12. RS-232C:Available (PC software at extra cost)
  13. Power:230 V + 10% AC, 50 Hz
  14. Dimensions:365 x 245 x 220 mm (L x B x H) (Approx.)
  15. Weight: Main Unit: 9Kg. (Approx.)


Pre-installation requireements :

We request to you make necessary arrangement of prerequisites LPG gas cylinder with regulator, double distilled water, NACL LR grade, KCL LR grade, NA standard solution (Minimum 5 solution Viz. 2 ppm, 4 ppm, 6 ppm, 10 ppm or as per requirement) and K standard solution (Minimum One Viz. 10 ppm or as per requirement), power supply 230 volt, 50 Hz 25 Amp power plug to carry out the demonstration at your site

INQUIRE NOW
name
company name
city
Email
Mobile number
requirments
message
Reset

Inquiry right arrow Inquiry left arrow INQUIRY

catalogue-image